SUN M8000主機 IOU板卡硬件更換
一、故障現象
1.日志分析
XSCF> showstatus
*IOU#0 Status:Degraded;
XSCF> showlogs -v error
Date: May 24 20:44:22 CST 2019???? Code: 80002000-33010000-0167058a00000000
Status: Alarm????????????????? Occurred: May 24 20:44:20.367 CST 2019
FRU: /IOU#0
Msg: DDC configuration error. DDC wrongly installed(detector=5)
Date: May 25 19:09:03 CST 2019???? Code: 80006000-33010000-0167058a00000000
Status: Alarm????????????????? Occurred: May 25 19:08:38.909 CST 2019
FRU: /IOU#0
Msg: DDC configuratin error. DDC wrongly installed(detector=5)
通過showstatus命令可以看到IOU#0已為降級狀態,IOU上裝有硬盤、HBA卡以及網卡等備件,IOU#0為降級狀態則運行不穩定,存在再次異常宕機隱患,一旦發生故障會影響操作系統正常運行,需要及時更換IOU#0模塊。
2.故障部件示意圖
IOU#0在M8000服務器上的安裝位置如下圖(紅色方框中的部件):
二、實施過程
1.確定故障件Domain
當前M8000服務器Domain劃分如下表:DomainCMUIOU備注
0CMU#0、CMU#1IOU#0
1CMU#2、CMU#3IOU#2
從Domain劃分可見,發生故障的CMU#1和IOU#0都屬于Domain 0。
2.確定版本
XSCF>? version -c xcp
XSCF#0 (Active )
XCP0 (Current): 1121
XCP1 (Reserve): 1121
XSCF#1 (Standby)
XCP0 (Current): 1121
XCP1 (Reserve): 1121
3.硬件更換
XSCF> showstatus
*IOU#0 Status:Degraded;
XSCF> replacefru
----------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU??? (CPU Memory Board Unit/IO Unit)
2. FAN??????? (Fan Unit)
3. PSU???? ???(Power Supply Unit)
4. XSCFU????? (Extended System Control Facility Unit)
5. DDC_A????? (DDC for BP_A)
----------------------------------------------------------------------
Select [1-5|c:cancel] :1
-----------------------------------------------------------------
Maintenance/Replacement Menu
Please select whether to replace a CMU only, an IOU only,
or both a CMU and an IOU.
1. Replace CMU only.
2. Replace IOU only.
3. Replace both CMU and IOU.
----------------------------------------------------------------
Select [1-3|b:back] :2
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select an IOU to be replaced.
DomainID
No. FRU?????????? XSB#0 XSB#1 XSB#2 XSB#3 Power Status
--- ------------- ----------------------- ----- ---------------
1. IOU#0???????????? 0???? 0???? 0???? 0? Off?? Degraded
2. IOU#1???????????? 0???? 0???? 0???? 0? Off?? Not installed
3. IOU#2???????????? 1???? 1???? 1???? 1? On??? Normal
4. IOU#3???????????? 1???? 1???? 1???? 1? On??? Not installed
----------------------------------------------------------------------
Select [1-4|b:back] :1
----------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the selected FRU.
FRU?????????? Status
------------- --------
IOU#0???????? Degraded
----------------------------------------------------------------------
You are about to replace IOU#0.
Do you want to continue?[r:replace|c:cancel] :r
Please confirm the Ready LED is not lit and that the Check LED is
blinking.
If this is the case, please replace IOU#0.開始拔出故障IOU板塊,將硬盤、HBA卡等配件按順序插入新的IOU板卡中,將新的IOU板卡插入SUN M8000,再進行下一步的操作
After replacement has been completed, please select[f:finish] :f
To ensure correct operation, diagnostic tests should be run on
IOU#0.[d:diagnose|s:skip] :d
Diagnostic tests for IOU#0 have started.
[This operation may take up to 60 minute(s)]
(progress scale reported in seconds)
0.....? 30.....? 60.....? 90..... 120..... 150..... 180..... 210.....done
----------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the selected FRU.
FRU?????????? Status
------------- --------
IOU#0???????? Normal#IOU板狀態正常
----------------------------------------------------------------------
The replacement of IOU#0 has completed normally.[f:finish] :f#完成配件更換